Mô đun chuyển đổi tần số 0-1KHZ sang 0-10V tại Lotte Market
Thương hiệu: | Xem thêm Mạch & Bộ phận điện Thương hiệuMô tả ngắn về Mô đun chuyển đổi tần số 0-1KHZ sang 0-10V tại Lotte Market
It can convert the frequency pulse signal to analog voltage signal, transform 0-1KHz frequency signal into 0-10V voltage output. Adjusting potentiometer can calibrate the relationships between frequency and voltage. F/V converter module, response time is around 0. Operating voltage: 13. Output voltage range: 0-10V. 35mm x 33mm x 14mm. Instructions for use. GND: Power ground. GND: input ground. GND: Output: Còn hàng
** Quét mã QR bằng Zalo để mua trên điện thoại
Giới thiệu Mô đun chuyển đổi tần số 0-1KHZ sang 0-10V tại Lotte Market
Description:
It can convert the frequency pulse signal to analog voltage signal, transform 0-1KHz frequency signal into 0-10V voltage output
Adjusting frequency can change output voltage, can be applied to interface conversion between PLC and frequency converter or interface matching control occasions like motion control card and frequency converter, etc
Adjusting potentiometer can calibrate the relationships between frequency and voltage
Signal input port adopts optocoupler isolation, which guarantees good anti-interference ability
F/V converter module, response time is around 0.3-0.5s. If the frequency is adjusted at one time by a large margin, a certain response time is required.
Specification:
Operating voltage: 13.5V-30V
Input frequency range: 0-1KHZ
Output voltage range: 0-10V
Size: Approx. 35mm x 33mm x 14mm
Note: The terminal part of the module is blue or green, sent in random.
Instructions for use
VCC: Operating power supply
GND: Power ground
F: A input frequency pulse signal
GND: input ground
VOUT: output corresponding voltage
GND: Output ground; Common ground for modules
Connect the operating voltage to VCC and GND. Do not reverse it to avoid damaging the board and the device.
Connect the frequency pulse signal to F and there is a corresponding voltage output at VOUT.
Input and output corresponding relationship: 100HZ=1V, 1KHZ=10V.
If there is a deviation in the correspondence between the use, adjust the potentiometer on the board to calibrate.
The module accuracy is 1%, and it cannot be applied to fields which has high demanding of precision.
Input different frequency, output will correspond to certain voltage.
Input pulse level can be 5V, 12V, 24V, serial resistor not needed. But if you input signal frequency, the time should be more than 0.5s
If you want to use it with PLC, it NPN. Please make sure that there is GND wire
If you want to use it with encoder, it requires constant rotation of the encoder for more than 0.5s
Package Includes:
1 Piece Frequency to Voltage Converter Module