Driver input signal interface function. PLS+ and PLS- are the positive and negative ends of the control pulse signal; DIR+ and DIR- are the positive and negative ends of the direction signal; ENA+ and ENA- are the positive and negative ends of the enable signal. Motor interface. When the A and B phase windings are exchanged, the direction of the
: Còn hàng
: Shopee
258.100đ 450.600đ
** Quét mã QR bằng Zalo để mua trên điện thoại

Giới thiệu Động Cơ Bước Dm556 Cho Động Cơ Bước 57 86 Series Vn tại Lotte Market

Driver input signal interface functionĐộng Cơ Bước Dm556 Cho Động Cơ Bước 57 86 Series Vn

Signal interface

PLS+ and PLS- are the positive and negative ends of the control pulse signal; DIR+ and DIR- are the positive and negative ends of the direction signal; ENA+ and ENA- are the positive and negative ends of the enable signal. 24V requires a series of 2K resistors

Motor interfaceĐộng Cơ Bước Dm556 Cho Động Cơ Bước 57 86 Series Vn
A+ and A- are connected to the positive and negative ends of the A-phase winding of the stepping motor; B+ and B- are connected to the positive and negative ends of the B-phase winding of the stepping motor. When the A and B phase windings are exchanged, the direction of the motor can be reversed.

Power connectorĐộng Cơ Bước Dm556 Cho Động Cơ Bước 57 86 Series Vn
Use DC power supply, the recommended working voltage range is 20-50VDC, the power supply is greater than 100W, according to the actual use, the input is not more than DC40V is a suitable choice

Indicator lightĐộng Cơ Bước Dm556 Cho Động Cơ Bước 57 86 Series Vn
The drive has two red and green indicator lights. The green light is the power indicator light. When the drive is powered on, the green light is always on; the red light is the fault indicator. When there is an overvoltage or overcurrent fault, the fault light is always on. After the fault is cleared, the red light is off. When the drive fails, only re-power on and re-enable to clear the fault.

Products include: 1*driveĐộng Cơ Bước Dm556 Cho Động Cơ Bước 57 86 Series Vn